ECO PHYSICS, INC.

ECO PHYSICS, INC.

Share

Think NOx! Wholesale scientific instrument sales, Chemiluminescence NOx, O2, CO2 and NH3 measuring capability. Stack emissions to atmospheric research.

Pulmonary function research systems.

12/23/2025

As the year comes to a close, we want to extend a heartfelt thank you to our wonderful employees, partners, and customers. Your support and dedication made this year a great success, and we truly appreciate each and every one of you.

Wishing you a joyful holiday season and a happy, healthy, and successful New Year!

10/07/2025

ECO PHYSICS, INC. is proud to sponsor and participate in the H2EA-NA Fall 2025 Conference at the University of Michigan’s North Campus next week! We're looking forward to the invaluable networking opportunities and the lineup of panels and presentations from leading experts in Hydrogen technology. We hope to see you there!

09/24/2025

Celebrating 30 Years of Excellence!
This month is a major milestone for ECO PHYSICS, Inc. as we are celebrating our 30th anniversary. We are incredibly grateful to our customers, partners, and team members who have made this journey possible. Your trust drives us to keep pushing the boundaries of science and technology for a cleaner and healthier future.

08/21/2025

ECO PHYSICS, INC. had an impactful presence at the recent conference, showcasing the CLD 88sp Analyzer with DeNOx 88 and the EXHALYZER® D. Attendees engaged in live demonstrations and discussions, exploring the vital role of these instruments in PCD research.
We are particularly excited about the EXHALYZER D's research application in Multiple Breath Washout and Lung Clearance Index , which are essential in the research of early disease detection and reseserch into treatment. Let's connect to discuss advancements in our field. D

07/22/2025

I'm preparing for the next phase of my career, more soon!

Photos from ECO PHYSICS, INC.'s post 07/22/2025

Summer is here, and it's a perfect time to send in your NOx analyzer for routine annual maintenance! The corn is getting tall and that means that summer is almost half over.
Let our service technician put your analyzer back in top form by replacing the worn components so that you will again get the best possible performance from your ECO PHYSICS NOx analyzer.

06/19/2025

Let's start with part 6 of the ECO PHYSICS knowledge series:
⚙️ The ozone generator – the key to chemiluminescence
In the last post, we got to know the photomultiplier tube (PMT) as the "eye" of the CLD system.
Today, we focus on the other side of the reaction: the ozone generator, without which chemiluminescence could not take place at all.

🌬️ How is ozone formed in the analyzer?
Ozone (O₃) is generated in the device by an electrical discharge – usually in a so-called corona discharge.
In this process, dry air or pure oxygen is passed through a high-voltage field, causing oxygen molecules (O₂) to split and recombine to form ozone (O₃).
🔌 The result: Freshly produced ozone is immediately ready for reaction with nitric oxide (NO).

🎯 Why is ozone so important for sensitivity?
The chemiluminescence reaction – i.e. the reaction of NO + O₃ → NO₂* + light – is only efficient if sufficient ozone is available.
📈 More ozone = stronger light emission = better measurement signal.
Therefore, the quality and stability of ozone generation has a direct influence on the sensitivity and precision of NOx measurement.

⚠️ Challenges in ozone production
The generation of ozone in the analyzer entails some technical requirements:
🧊 Dry air is essential – moisture can inhibit ozone formation and damage components.
🔋 Stable high voltage is necessary – voltage fluctuations lead to uneven ozone production.
🛠️ Material resistance – Ozone is highly reactive and requires special, ozone-resistant materials in the device design.
➡️ High-quality devices such as those from ECO PHYSICS therefore rely on durable, precisely controlled ozone generators for constant performance.

✅ Result
The ozone generator is one of the heart of CLD technology.
Only with a stable ozone source can high-precision, reproducible NOx measurements be carried out – a must for demanding applications in the environment, research and industry.

🔍 View
In the next part, we will look at why the ozone produced must be destroyed again after the reaction – and what methods are available for this.
🧯 Part 7: The ozone destroyer – necessary for safety and equipment life.

🤝 If you would like to know more about the CLD measurement method or the possibilities of gas analysis for NO/NO₂/NOx, NH₃ or ozone, simply contact Anthony Groat, Ahmad Nabiyar or Tom McKarns at ECO PHYSICS, INC.
Thanks to Jörg Hoffmann of ECO PHYSICS GmbH who wrote this post.

06/12/2025

What is Juneteenth?

Juneteenth is a significant date in American history and the African American experience. The name is a play on the date of June 19th, 1865. On that day, the Union Army made its way into Galveston, TX under the leadership of General Gordon Granger, and he announced to the people of Texas that all enslaved African Americans were free.
Even though we know that the Emancipation Proclamation freed African Americans in rebelling states (Texas being one of them, from as early as it when the Proclamation went into effect on January 1st, 1863) and we know that the Civil War had ended in April of 1865, it took a while for freedom to make its way to the western most rebelling state. Although there were enslavers who were aware of the implementation of the Emancipation Proclamation, it wasn’t until June 19th, 1865 that it was actually enforced with the Union Army. June 19th freed enslaved people in the rebelling states, it did not free enslaved people throughout the nation.

Mary Elliott, Curator of American Slavery
Smithsonian National Museum of African American History and Culture

Want your school to be the top-listed School/college in Ann Arbor?

Click here to claim your Sponsored Listing.

Location

Telephone

Address


3915 Research Park Drive Ste 3A
Ann Arbor, MI
48108

Opening Hours

Monday 8am - 5:45pm
Tuesday 8am - 5:45pm
Wednesday 8am - 5:45pm
Thursday 8am - 5:45pm
Friday 8am - 5:45pm