๐๐จ๐ฐ๐๐ซ ๐๐ฎ๐๐ฅ๐ข๐ญ๐ฒ ๐๐ก๐๐ฅ๐ฅ๐๐ง๐ ๐๐ฌ ๐ข๐ง ๐ญ๐ก๐ ๐๐จ๐๐๐ซ๐ง ๐๐ฅ๐๐๐ญ๐ซ๐ข๐๐๐ฅ ๐๐๐ง๐๐ฌ๐๐๐ฉ๐
A productive session with electrical engineering consultants, discussing how modern loads are reshaping power system behaviourโand why traditional design approaches are no longer sufficient.
Key discussions included:
* Emerging power quality challenges in todayโs systems
* The importance of accurate measurement & monitoring
* Limitations of conventional capacitor banks
* Practical approaches using modern PQ solutions
Good engagement, practical questions, and valuable exchange of real project experiences.
We at PQE Power System Sdn Bhd thank all participants for the active discussion.
24/04/2026
๐๐๐ฌ๐ญ๐๐ซ๐ข๐ง๐ ๐๐จ๐ฐ๐๐ซ ๐๐ฎ๐๐ฅ๐ข๐ญ๐ฒ ๐ข๐ง ๐๐จ๐ฅ๐๐ซ ๐๐ ๐๐ฒ๐ฌ๐ญ๐๐ฆ๐ฌ โ 2๐ง๐ ๐๐๐ฌ๐ฌ๐ข๐จ๐ง
Following the strong response from our earlier session, we were pleased to host another round of focused discussions with Solar PV stakeholders.
As Solar PV and BESS adoption accelerates, power quality is becoming a key factor in ensuring stable, efficient, and reliable system performance.
This session centred on practical insights into measurement, performance optimisation, and reducing energy losses โ reinforcing the importance of going beyond installation.
Thank you to all participants for your continued engagement.
Driving better solar performance takes more than generation โ it takes collaboration.
14/04/2026
Installing a Solar PV system is only the first step.
โWhat challenges are you facing after PV installation?โ
- Frequent tripping and system instability
- Difficulty meeting grid and compliance requirements
- Integration challenges with existing electrical systems
As Solar PV adoption continues to grow, the focus must go beyond installation. Achieving stable operation, compliance, and optimal performance requires deeper visibility and a clearer understanding of how solar interacts with the overall electrical system.
This is a critical step towards delivering more reliable, efficient, and high-performance solar solutions.
10/04/2026
โ๐๐จ๐๐๐ซ๐ง ๐๐ฅ๐๐๐ญ๐ซ๐ข๐๐๐ฅ ๐ฌ๐ฒ๐ฌ๐ญ๐๐ฆ๐ฌ ๐๐ซ๐ ๐ง๐จ ๐ฅ๐จ๐ง๐ ๐๐ซ ๐๐๐๐ข๐ง๐๐ ๐๐ฒ ๐ฌ๐ข๐ฆ๐ฉ๐ฅ๐, ๐ฉ๐ซ๐๐๐ข๐๐ญ๐๐๐ฅ๐ ๐ฅ๐จ๐๐ ๐ฉ๐ซ๐จ๐๐ข๐ฅ๐๐ฌ.โ
Todayโs networks are shaped by non-linear loads โ variable speed drives, data centres, EV chargers, and power electronics โ all contributing to increasingly complex harmonic signatures across the system.
Yet, many measurement practices still stop at the 50th harmonic order, creating critical blind spot in modern operations.
Higher-order harmonics โ often dismissed or simply unmeasured โ can introduce:
* Additional thermal stress on transformers and cables
* Interference with sensitive electronics and control systems
* Reduced effectiveness of conventional filtering solutions
When these components remain outside your visibility, power system behaviour becomes harder to explain and control.
What is not capturedโฆ is not analysed. And what is not analysedโฆ is not managed..
At PQE Power System Sdn Bhd, we believe accurate data is the starting point of every reliable and suitable solution.
Extending harmonic analysis beyond conventional limits enables:
โ Deeper understanding of true system conditions
โ More precise mitigation strategies
โ Improved long-term reliability and asset performance
In todayโs ever-growing electrical landscape, measurement boundaries should not define system understanding.
See beyond the standard. Measure what truly matters!
02/04/2026
Due to overwhelmingly positive response from our previous session, weโre opening a second session focused on power quality in solar PV systems. โ๏ธ
As solar adoption grows, so do the practical challenges surrounding integration, stability, and system performance.
This session is designed for solar providers to exchange insights on how power quality considerations can support better outcomes; not just in installation, but in long-term power system's power quality and performance. โก
๐ Limited seats to ensure meaningful discussion
๐
22 April 2026 | 9AM โ 12PM
๐ Register here: https://forms.office.com/r/ektFexeAQ0
01/04/2026
๐๐ซ๐ ๐ฒ๐จ๐ฎ๐ซ ๐ฉ๐ซ๐จ๐ญ๐๐๐ญ๐ข๐จ๐ง ๐ซ๐๐ฅ๐๐ฒ๐ฌ ๐ฌ๐ญ๐ข๐ฅ๐ฅ ๐ซ๐๐ฅ๐ข๐๐๐ฅ๐โ๐จ๐ซ ๐ฃ๐ฎ๐ฌ๐ญ ๐ฉ๐๐ฌ๐ฌ๐ข๐ง๐ ๐ญ๐๐ฌ๐ญ๐ฌ?
With increasing system complexityโVFDs, solar integration, and non-linear loadsโrelay performance can drift without obvious signsโฆ until a false trip or failure occurs.
โก ๐๐ฎ๐ฅ๐ญ๐ข-๐๐จ๐ข๐ง๐ญ ๐๐๐ฌ๐ญ๐ข๐ง๐ ๐๐๐ญ๐ญ๐๐ซ๐ฌ
Protection curves are not a single point.
Testing across multiple injection points ensures your relay responds correctly across real operating conditionsโnot just one setting.
โฑ ๐๐ซ๐ข๐ฉ๐ฉ๐ข๐ง๐ ๐๐ข๐ฆ๐ ๐๐ฌ ๐๐ซ๐ข๐ญ๐ข๐๐๐ฅ
A relay that trips is not enough.
It must trip within the correct time windowโtoo fast or too slow can both lead to coordination issues, equipment damage, or unnecessary shutdowns.
โ ๏ธ Todayโs risk isnโt just failureโitโs misoperation.
Incorrect settings, ageing components, and system changes can silently compromise protection.
๐๐ซ๐๐๐ข๐ฌ๐ข๐จ๐ง ๐ข๐ฌ๐งโ๐ญ ๐จ๐ฉ๐ญ๐ข๐จ๐ง๐๐ฅโ๐ข๐ญโ๐ฌ ๐๐ซ๐ข๐ญ๐ข๐๐๐ฅ ๐ญ๐จ ๐ซ๐๐ฅ๐ข๐๐๐ฅ๐ ๐จ๐ฉ๐๐ซ๐๐ญ๐ข๐จ๐ง.
๐ฌ Not sure if your relay settings still match your current system? Letโs talk.
31/03/2026
For more updates and newsletters, visit our website at www.PQE.com.my
31/03/2026
๐๐จ๐ง๐ฏ๐๐ง๐ญ๐ข๐จ๐ง๐๐ฅ ๐๐๐ฉ๐๐๐ข๐ญ๐จ๐ซ ๐๐๐ง๐ค๐ฌ ๐๐จ๐งโ๐ญ ๐๐๐ข๐ฅ ๐๐ฒ ๐๐๐๐ข๐๐๐ง๐ญโ๐ญ๐ก๐๐ฒ ๐๐๐ข๐ฅ ๐จ๐ง ๐ฌ๐๐ก๐๐๐ฎ๐ฅ๐.
Every switching event engages contactors, reactors, and stepped capacitor stages, generating..
- Contact arcing
- Thermal cycling
- Introduce harmonics from VFD-driven motors, EV chargers, and solar inverters
- Dielectric stress, reactor saturation, and switchgear fatigue accelerate, quietly eroding system reliability.
This is a design flaw in relation to our modern day power system demand response. Step-based capacitor banks assume loads are slow-changing and linear, but modern electrical systems are dynamic, non-linear, and digitally controlled. When your reactive power compensation depends on consumable electromechanical components, predictable failure isnโt just likely; itโs engineered into the system.
The consequences?? Voltage excursions, nuisance breaker trips, harmonic amplification, and power factor penalties increase OPEX, strains downstream equipment, and shortens the lifecycle of inverters, transformers, and switchgear.
Systems that fail โon scheduleโ silently degrade overall power quality while giving operators the illusion of normal operations.
Solution! Modern loads demand solid-state, real-time reactive power solutions that handle rapid load transients without mechanical bottlenecks or built-in failure points. If your capacitor bank still relies on stepped stages, contactors, and reactors, itโs already obsolete in todayโs dynamic power system landscape.
30/03/2026
Harmonic measurement standards have evolved โ but field practices are lagging behind. โก
While earlier benchmarks focused on 50th harmonic orders, decades have passed and modern international expectations now extend to 100th as per UK Engineering Recommendation G5/5.
Yet many marketed power measurement tools remain configured to outdated standards..
The question is: are we comfortable making decisions based on outdated visibility & measurement tools?
27/03/2026
A focused session on Mastering Power Quality in Solar PV Systems.
As solar PV systems and related technologies such as BESS' adoption accelerates, power quality increasingly determines how efficiently energy is delivered, utilised, and sustained across the end users' power systems. Solar PV systems' power generation is innovativeโ but like all real-world systems, performance depends on how well limitations are understood and managed.
This session brought solar PV system stakeholders together to explore practical measurement insights, performance optimisation, and collaborative approaches to reducing energy losses.
Maximising solar efficiency works best when industry partners work together.
Thank you again to all participants for your valuable engagement and contributions!