19/01/2026
A Leading Company is Hiring Fresh Graduate Engineers
A well-established company in the Oil & Gas sector is seeking fresh graduate engineers to join its growing team.
Required Specializations:
Communication Engineering
Power Engineering
Preferred Qualifications:
ITI Automation Diploma or
Strong interest in Automation systems (PLC & DCS)
Work Location: Alexandria
How to Apply:
Interested candidates are kindly requested to fill out the application form below:
👉
https://docs.google.com/forms/d/e/1FAIpQLSdZdJCa5vYoJzt-tPes3t3NrIL7LvOzMiD3N5MpSIvxU6tl6g/viewform?usp=sharing&ouid=105620216747335258161
Feel free to share with anyone who might be interested!
docs.google.com
06/02/2025
بشرى لمهندسين اسكندرية والبحيرة خاصة ,ومتاح التقديم للجميع الأفضلية لخريجى الجامعات الحكومية
مطلوب عدد 6 مهندس تحكم الى مؤهل مناسب للعمل بموقع بترولى فى الاسكندرية
بفضل الخبرة بأنظمة الPLC DCS and SCADA
direct link for job
docs.google.com
31/12/2024
مطلوب مهندسين وفنيين أجهزة وتحكم الى لموقع بترولى في الاسكندرية خبرة أكثر من 3 سنوات فى صيانة الاجهزة والتحكم و البلوف و المعايرات
نظم التحكم PLC and DCS
العمل بنظام المياومة عقد مدة طويلة واحتمالية التثبيت فى شركة تابعة لهيئة البترول
اليومية حسب السنوات التأمينية
السن لا يزيد عن 40 سنة
send your CV to
[email protected]
24/10/2024
Saipem hashtag - hashtag
LOCAL hashtag RESOURCES ARE STONGLY ENCOURAGED TO APPLY -
hashtag / Warehouseman
hashtag Specialist
hashtag / Instrument Technician
hashtag Technician
hashtag Equipment Specialist
hashtag Specialist
hashtag (Workshop Specialist)
Please identify the position applied for as per the description mentioned above. Send CV's to [email protected]
وده ليتك صفحتى ملهاش دعوة بالاعلان بس تشجيع منكم https://www.facebook.com/letscreateeg/
07/07/2024
Let's Create
مؤسسة تعليمية غير هادفة للربح تقدم خدمات ودورات مجانية أو بسعر التكلفة يهمنا الارتقاء بتعليم الطفل
23/04/2024
مطلوب
١-محاضر ل كورس روبوت
الشروط خبرة لا تقل عن سنتين في كورسات مع الأطفال
القدرة علي الابتكار ومناقشة الأطفال في الأفكار والحلول المتعددة
المشاركة في إعداد المنهج و متطلبات تن
فيذه
٢-مطلوب محاضر لانشطة استيم
خبرة في اعداد فاعليات اليوم الواحد و الكامبات
علي دراية كاملة بتطبيق التعلم بنظام استيم و مهارات الطالب والمعلم في القرن الحادي والعشرين
يفضل من لديه شهادة احترافية في المجال
٣- محاضرين برمجة و جرافيك اون لاين او اوف لاين
الفاعليات والانشطة الحضورية مكانها اسكندرية
we are exploring the integration of STEAM (Science, Technology, Engineering, Arts, and Mathematics) education into our courses. Given the innovative nature of your teaching methods, could you please elaborate on how STEAM education principles are incorporated into your courses? We are particularly interested in understanding the synergies between your teaching approach and the goals of our organization.
يرجي ارسال السيرة الذاتية في رسالة هنا او علي رقم واتس 01284646181
موضحا فيه الخبرة و مجيبا علي السؤال اعلاه
Company Description
We provide online educational services for kids, specializing in programming, AI, and graphic design. Our goal is to enhance children's education and develop their critical thinking and logical minds. With our comprehensive courses, we offer a unique learning experience that combines creativity and technology. Our interactive curriculum is designed to engage young minds, fostering a love for learning and empowering them to become future innovators.
Through our programming courses, children learn the fundamentals of coding and problem-solving. They gain practical skills in languages like Scratch and Python, building their own games, apps, and websites. Our AI courses introduce them to the exciting world of artificial intelligence, where they explore concepts like machine learning and robotics.
In our graphic design courses, children unleash their creativity and develop visual communication skills. They learn how to create stunning graphics, illustrations, and animations using industry-standard tools. Our goal is to empower them to express their ideas visually and develop a keen eye for design.
We believe in the power of critical thinking and logical reasoning. Our courses go beyond technical skills, encouraging children to think analytically and approach challenges with a problem-solving mindset. We nurture their curiosity, allowing them to explore and experiment in a supportive and safe online environment.
Join us on this educational journey as we inspire and empower the next generation of creators, problem solvers, and innovators. Follow our page to stay updated on our latest courses, success stories, and educational insights.
Invest in your child's future today and let us be your partner in their educational growth. Together, we can prepare them for a world that values creativity, technology, and critical thinking.
Role Description
This is a part-time hybrid role, based in Alexandria, Egypt, with flexibility for remote work. As a (Robotics , Programming, STEAM Courses Trainer), you will be responsible for delivering high-quality training sessions on robotics and programming courses.
Qualifications
Fluency in both Arabic and English
Strong knowledge and experience in robotics and programming
Ability to create engaging and interactive training sessions for children
Excellent communication and presentation skills
Patience, creativity, and passion for teaching
Experience working with children or in an educational setting is a must
"
23/12/2023
معلومة مهمة جدا عن متابعة الأولاد الفيديو موجود علي https://www.facebook.com/letscreateeg
Let's Create
مؤسسة تعليمية غير هادفة للربح تقدم خدمات ودورات مجانية أو بسعر التكلفة يهمنا الارتقاء بتعليم الطفل
12/07/2023
Which of the following statements about control valve installation practices is false?
(A) If the material is not hazardous, vent lines are not needed for fluid trapped between stop valves.
(B) Valves must be located where an operator can see indicators or gages needed for manual control.
(C) Lines should be flushed or blown out before valve installation.
(D) Higher flow velocities are allowed in gas lines than in liquid or steam lines.
Explanation of why the other choices are true:
(B) Valves must be located where an operator can see indicators or gauges needed for manual control: This statement is true. Placing valves in a location where operators can easily access and monitor indicators or gauges is important for efficient manual control and operation.
(C) Lines should be flushed or blown out before valve installation: This statement is true. Flushing or blowing out lines before valve installation helps remove debris, contaminants, or foreign materials that could potentially damage or affect the performance of the valve. It is a standard practice to ensure the integrity of the control system.
The correct answer is (A); vent lines should be provided so that personnel or equipment will not be inadvertently sprayed, even with harmless material, when a vent valve is opened. (See J. W. Hutchison, pp. 336-337.)
11/07/2023
Which of the following statements about control valve installation practices is false?
(A) At least 10-20 pipe diameters of straight run inlet piping should be provided upstream of control valves.
(B) At least 3-5 pipe diameters of straight run piping should be provided downstream of control valves.
(C) Diaphragm-actuated control valves must be installed with the stem in a vertical (upward) position.
(D) Valves must be installed with the flow arrow in the correct direction.
Explanation of why the other choices are true:
(A) At least 10-20 pipe diameters of straight run inlet piping should be provided upstream of control valves: This statement is true. Sufficient straight run piping upstream of a control valve helps to ensure proper flow profile, reduces turbulence, and allows for stable control.
(B) At least 3-5 pipe diameters of straight run piping should be provided downstream of control valves: This statement is true. Adequate straight run piping downstream of a control valve helps to prevent flow disturbances, such as swirling or recirculation, and allows for smooth flow and accurate control.
(D) Valves must be installed with the flow arrow in the correct direction: This statement is true. Installing valves in the correct flow direction is crucial for their proper operation. Flow arrows on the valve body indicate the correct direction of fluid flow and should be followed during installation.
However, (C) Diaphragm-actuated control valves must be installed with the stem in a vertical (upward) position is a false statement. The orientation of diaphragm-actuated control valves does not require the stem to be in a specific vertical (upward) position. Diaphragm-actuated control valves can be installed in any suitable orientation based on the piping layout and operational requirements.
Therefore, the false statement is (C) Diaphragm-actuated control valves must be installed with the stem in a vertical (upward) position.
10/07/2023
A safety barrier limits the energy transfer to a hazardous location by limiting the maximum current (using a fuse) and shunting any high-voltage faults in the safe area to a safety ground (through Zener diodes).
Which of the following considerations does NOT apply to a shunt Zener Diode barrier?
(A) Requires an intrinsically safe ground
(B) Can cause voltage drop problems
(C) Is expensive and difficult to use
(D) Fuse can blow during startup
Here's an explanation of why the other choices are incorrect:
(A) Requires an intrinsically safe ground: A shunt Zener diode barrier requires a proper grounding arrangement to ensure that any high-voltage faults are safely shunted to ground. This is necessary to prevent hazardous energy transfer to the safe area. Therefore, this consideration applies to a shunt Zener diode barrier.
(B) Can cause voltage drop problems: When a fault occurs and the Zener diodes shunt the high voltage to ground, there can be some voltage drop across the Zener diodes. This voltage drop can cause a reduction in the voltage available to the equipment in the safe area. Therefore, voltage drop problems are a consideration when using a shunt Zener diode barrier.
(D) Fuse can blow during startup: The fuse in a shunt Zener diode barrier is designed to limit the maximum current and protect the system. During startup, there can be transient currents or inrush currents that may cause the fuse to blow. Therefore, the possibility of the fuse blowing during startup is a consideration for a shunt Zener diode barrier.
(C) Is expensive and difficult to use: This consideration does not apply to a shunt Zener diode barrier. Shunt Zener diode barriers are generally considered cost-effective and relatively easy to use compared to other types of safety barriers, such as intrinsic safety barriers or galvanic isolation barriers. They are widely used in hazardous area applications due to their simplicity and effectiveness.
In summary, the consideration that does NOT apply to a shunt Zener diode barrier is (C) Is expensive and difficult to use.