Victorian Electrical Inspectors

Victorian Electrical Inspectors Victoria’s premier training school for G Class Electrical Inspectors, a division of TTA — Technical Training Australia. Small classes.

Experience the best training in Victoria. Best G Class LEI training materials and 30+ training boards.

Congratulations Dale on passing your G Class Practical Assessment today with a whopping big 85% 🏆🥇⚡️👏🏼👏🏼, we are all so ...
19/08/2026

Congratulations Dale on passing your G Class Practical Assessment today with a whopping big 85% 🏆🥇⚡️👏🏼👏🏼, we are all so proud of you Dale, you are going to make a great Licensed Electrical Inspector for NE rural Victoria.

Dedicated study from early morning to evening, day after day. He’s smart, he’s knows his stuff and knew he’d get there.

“He came, he camped, he conquered “ 😊

Congratulations Kamal, you deserve this, very proud of you.You are Victoria’s next G Class Inspector.Kamal started at TT...
31/07/2026

Congratulations Kamal, you deserve this, very proud of you.
You are Victoria’s next G Class Inspector.
Kamal started at TTA 1 year ago, trained and passed G Class Safe Approach, then Practical and passed this week.
Watch this space for his new Poster going on the wall in the LEI classroom.




Hi there TTA Electrical Inspectors. When visually inspecting the labelling for a safety service, AS/NZS 3000:2018 clause...
16/06/2026

Hi there TTA Electrical Inspectors.
When visually inspecting the labelling for a safety service, AS/NZS 3000:2018 clause 7.2.4.4 (b) says the Main Switch must be labelled with the correct lettering.
Which lettering is correct and which lettering is not compliant according to AS/NZS 3000:2018?





Hi there TTA Electrical Inspectors. Did you know that you can earth a switchboard enclosure with a neutral conductor?AS/...
14/06/2026

Hi there TTA Electrical Inspectors. Did you know that you can earth a switchboard enclosure with a neutral conductor?

AS/NZS 3000:2018 Clause 5.5.3.5(a) gives us this option as shown on page 298.

Of course, we generally earth metal enclosures with an earthing conductor. But for those studying their electrical Inspectors assessments, you need to be aware that a metallic construction switchboard may have a full-size neutral conductor that is providing the earthing for the switchboard enclosure.
While this is unusual as an everyday practice, this is not a defect for this switchboard.

As in other Australian states, where an earth is not available, a metallic structure can be earthed through a supply neutral conductor.



Hi there TTA Electrical Inspectors. Do you know the difference between different brands of socket outlets. Not all socke...
11/06/2026

Hi there TTA Electrical Inspectors.
Do you know the difference between different brands of socket outlets.
Not all socket outlets are the same.
Some have friction fit terminals for the 3 pin plug top.
Some have spring fit terminals that give a very good connection to the 3 pin plug top.
Remember, brass terminals are hard wearing, whereas copper connection are not hard wearing.
Cooper connections do not like heavy current loads with high temperatures. Whereas, brass terminals will be both hard wearing and good with high current temperatures.




Hi there TTA electrical inspectors. Did you know that DIN rail socket outlets are a switched socket outlet. Yes, the act...
07/06/2026

Hi there TTA electrical inspectors.
Did you know that DIN rail socket outlets are a switched socket outlet. Yes, the active and neutral conductors are switched as you insert a 3 pin plug into the socket outlet.
Also, as you insert the 3 pin socket outlet you switch a neon indicator into the circuit. However, when testing the socket outlet without power, there is a 20 Meg Ohm resistor connected in series with the neon indicator lamp.
So, when testing for your safe approach assessment, you will find a 20 Meg Ohm test result between active and neutral terminals. This is not a fault.





Studying for your G Class license all begins with your theory assessment 📚📖.  offers Daytime and After Hours or Remote l...
06/06/2026

Studying for your G Class license all begins with your theory assessment 📚📖.
offers Daytime and After Hours or Remote learning course options.
We are flexible to suit your daily schedule.
Call 📲 us now to find out how.
0385555050 or technicaltrainingAustralia.com.au

Can you spot the visual defect TTA Electrical Inspectors?The left hand DIN rail socket outlet is compliant. The right ha...
06/06/2026

Can you spot the visual defect TTA Electrical Inspectors?
The left hand DIN rail socket outlet is compliant. The right hand DIN rail socket outlet is not compliant as the neutral conductor is 1.5 mm with a 2.5 mm active conductor.
Wiring Rule 3.5.2 (a)(i)





Hi there TTA Electrical Inspectors. Did you know that Neutral conductors must have the same current carrying capacity as...
05/06/2026

Hi there TTA Electrical Inspectors.
Did you know that Neutral conductors must have the same current carrying capacity as the associated active conductor.
Wiring Rule 3.5.2 (a) (i)
So, if you have a socket outlet, in a construction switchboard, wired in building wire, the active and neutral conductors must be the same size.
Watch out for this technical/visual defect in the safe approach assessment.
Sometimes this is hard to see in a dark switchboard enclosure with black neutral conductors.
So, TTA inspectors have a good look.





Address

11 Bastow Place, Mulgrave
Melbourne, VIC
3170

Opening Hours

Monday 9am - 7pm
Tuesday 9am - 7pm
Wednesday 9am - 7pm
Thursday 9am - 7pm
Friday 9am - 4pm
Saturday 9am - 12pm

Telephone

+61385555050

Alerts

Be the first to know and let us send you an email when Victorian Electrical Inspectors posts news and promotions. Your email address will not be used for any other purpose, and you can unsubscribe at any time.

Shortcuts

Featured

Share

Category